Industrial Burners

FUSE

FUSE RR

RR Circular Refractory

Circular Section Refractory Combustion Nozzle

  1. Thanks to its patented special design, the conical bowl turbulator provides an excellent combustion performance.
  2. With the help of a special mechanism placed on the turbulator, the air that will join combustion can be directed to the center of the turbulator or its surroundings, and thus achieving optimum combustion performance.
  3. Emission values are obtained at desired levels with the help of fresh air integrated into the gas line from special points.
  4. In addition, the amount of fresh air mixed with the gas can be adjusted with the help of a special mechanism located in one of the pre-mixing zones.
  5. RR code refers to circular section refractory nozzle.

Properties

  • Capacity range of 150-6000 kW
  • Gas fired combustion
  • Ability to operate with ambient air or preheated air
  • Excess air capacity
  • Square and circular section refractory nozzle options for fiber and concrete walls
  • Direct ignition
  • Photocell and ionization options as flame detectors
  • Elegant and functional design

Advantages

  • Economical fuel consumption
  • Short cycle times
  • Homogeneous heat distribution in the furnace
  • Excellent flame stabilization
  • High modulation
  • Option to operate as a one stage at high capacities
  • Low NOx and CO emission values

Areas of Use

  • Forging processes
  • Reheat processes
  • Pot heating processes
  • Casting vessel heating processes
  • Scrap preheating processes
  • Stress relief processes
  • Aluminum melting processes
  • Thermal fluid heaters
  • Thermal oxidizers
  • Refractory drying units
  • Glass tank heating systems
  • Fiber blanket processing furnaces are used in all other heat treatments and processes that require high temperature and flame stability, tunnel or car furnaces, stretching furnaces, ceramic furnaces, fiber insulated furnaces, etc. used in industrial processes.
HIGH SPEED FUSE SERIES
BURNER PRODUCT FAMILY
BODY
TYPE
SS SERİSİ BURNER CAPACITY BURNER CAPACITY NATURAL GAS CONSUMPTIONİ INCOME
Circular
Refractory Combustion
Headed
MINIMUM
(kW)
MAXIMUM
(kW)
MINIMUM
(kcal/h)
MAXIMUM
(kcal/h)
MINIMUM
(Nm3/h)
MAXIMUM
(Nm3/h)
VAC
FUSE-2 FUSE-RR0150-HI 60 150 51600 129000 6,25 15,64 1N 230/3N 400
FUSE-RR0200-HI 80 200 68800 172000 8,34 20,85 1N 230/3N 400
FUSE-3 FUSE-RR0400-HI 160 400 137600 344000 16,68 41,70 1N 230/3N 400
FUSE-RR0500-HI 200 500 172000 430000 20,85 52,12 1N 230/3N 400
FUSE-RR0600-HI 240 600 206400 516000 25,02 62,55 1N 230/3N 400
FUSE-4 FUSE-RR1200-HI 480 1200 412800 1032000 50,04 125,09 1N 230/3N 400
FUSE-RR1600-HI 640 1600 550400 1376000 66,72 166,79 1N 230/3N 400
FUSE-5 FUSE-RR3500-HI 1500 3500 1290000 3010000 156,36 364,85 1N 230/3N 400
FUSE-RR4250-HI 1800 4250 1548000 3655000 187,64 443,03 1N 230/3N 400
FUSE-RR5000-HI 2100 5000 1806000 4300000 218,91 521,21 1N 230/3N 400
HIGH SPEED FUSE SERIES
BURNER PRODUCT FAMILY
BODY
TYPE
SS SERİSİ BURNER CAPACITY BURNER CAPACITY NATURAL GAS CONSUMPTIONİ INCOME
Circular
Refractory Combustion
Headed
MINIMUM
(kW)
MAXIMUM
(kW)
MINIMUM
(kcal/h)
MAXIMUM
(kcal/h)
MINIMUM
(Nm3/h)
MAXIMUM
(Nm3/h)
VAC
FUSE-2 FUSE-RR0150-UL 60 150 51600 129000 6,25 15,64 1N 230/3N 400
FUSE-RR0200-UL 80 200 68800 172000 8,34 20,85 1N 230/3N 400
FUSE-RR0250-UL 100 250 86000 215000 10,42 26,06 1N 230/3N 400
FUSE-3 FUSE-RR0400-UL 160 400 137600 344000 16,68 41,70 1N 230/3N 400
FUSE-RR0500-UL 200 500 172000 430000 20,85 52,12 1N 230/3N 400
FUSE-RR0600-UL 240 600 206400 516000 25,02 62,55 1N 230/3N 400
FUSE-RR1000-UL 400 1000 344000 860000 41,70 104,24 1N 230/3N 400
FUSE-4 FUSE-RR1200-UL 480 1200 412800 1032000 50,04 125,09 1N 230/3N 400
FUSE-RR1600-UL 640 1600 550400 1376000 66,72 166,79 1N 230/3N 400
FUSE-RR2000-UL 900 2000 774000 1720000 93,82 204,48 1N 230/3N 400
FUSE-5 FUSE-RR3500-UL 1500 3500 1290000 3010000 156,36 364,85 1N 230/3N 400
FUSE-RR4250-UL 1800 4250 1548000 3655000 187,64 443,03 1N 230/3N 400
FUSE-RR5000-UL 2100 5000 1806000 4300000 218,91 521,21 1N 230/3N 400
FUSE-RR6000-UL 2600 6000 2236000 5160000 271,03 625,45 1N 230/3N 400
BODY
TYPE
RR SERIES A ØB C ØD E F □G ØH I
Circular
Refractory Combustion
Headed
FUSE-2 FUSE-RR0150-HI 680 Ø110 345 Ø190 DN25 DN50 □230 Ø230 15
FUSE-RR0200-HI 680 Ø110 345 Ø190 DN25 DN50 □230 Ø230 15
FUSE-3 FUSE-RR0400-HI 895 Ø170 395 Ø250 DN40 DN100 □300 Ø320 15
FUSE-RR0500-HI 895 Ø170 395 Ø250 DN40 DN100 □300 Ø320 15
FUSE-RR0600-HI 895 Ø170 395 Ø250 DN40 DN100 □300 Ø320 15
FUSE-4 FUSE-RR1200-HI 855 Ø250 395 Ø330 DN50 DN150 □450 Ø450 15
FUSE-RR1600-HI 855 Ø250 395 Ø330 DN50 DN150 □450 Ø450 15
FUSE-5 FUSE-RR3500-HI You can contact our Ecostar
sales team to get information about the dimensions of our products with FUSE-5 body.
FUSE-RR4250-HI
FUSE-RR5000-HI

BODY
TYPE
RR SERIES A ØB C ØD E F □G ØH I
Circular
Refractory Combustion
Headed
FUSE-1 FUSE-RR0100-UL 645 Ø100 345 Ø190 DN15 DN40 □230 Ø230 15
FUSE-2 FUSE-RR0150-UL 680 Ø110 345 Ø190 DN25 DN50 □230 Ø230 15
FUSE-RR0200-UL 680 Ø110 345 Ø190 DN25 DN50 □230 Ø230 15
FUSE-RR0250-UL 680 Ø110 345 Ø190 DN25 DN50 □230 Ø230 15
FUSE-3 FUSE-RR0400-UL 895 Ø170 395 Ø250 DN40 DN100 □300 Ø320 15
FUSE-RR0500-UL 895 Ø170 395 Ø250 DN40 DN100 □300 Ø320 15
FUSE-RR0600-UL 895 Ø170 395 Ø250 DN40 DN100 □300 Ø320 15
FUSE-RR1000-UL 895 Ø170 395 Ø250 DN40 DN100 □300 Ø320 15
FUSE-4 FUSE-RR1200-UL 855 Ø250 395 Ø330 DN50 DN150 □450 Ø450 15
FUSE-RR1600-UL 855 Ø250 395 Ø330 DN50 DN150 □450 Ø450 15
FUSE-RR2000-UL 855 Ø250 395 Ø330 DN50 DN150 □450 Ø450 15
FUSE-5 FUSE-RR3500-UL You can contact our Ecostar
sales team to get information about the dimensions of our products with FUSE-5 body.
FUSE-RR4250-UL
FUSE-RR5000-UL
FUSE-RR6000-UL