Industrial Burners

DIB

DIB 600.3

  • ECOSTAR DIB series industrial burners with duoblock body structure are used in steam boilers, hot oil boilers, start-up applications and hot air generators.
  • Natural gas, LPG, Heavy Oil, Light Oil, Biogas and special fuels can be used.
  • With different combustion nozzle designs and flame pipe lengths suitable for the process, it can work in harmony in different combustion chambers, including modernized applications.
  • Able to operate at combustion air fan suitable for the process and at 200°C combustion air temperatures. (It is painted with high temperature resistant paint; product capacity varies in hot air operation.)
  • Suitable for manufacturing from completely stainless material in processes that require chemical resistance.
  • Possible to request as mechanical, electronic and modulating depending on the process needs.
  • Light oil filtering and pumping station is produced externally according to customer demand.
  • Light oil filtering, heating and pumping station are produced externally according to customer demand.
  • Special design pilot ignition burners are available for ignition (ECOSTAR PAL burner is standard in DIB-500 series and above).
  • Combustion optimization with O2-CO trim system adaptation in electronic proportional burners, if demanded.
  • Energy saving with fan speed control in electronic proportional burners, if demanded.
  • Remote management by connecting to PLC systems using BMS (Burner Management System) or software.
  • High fire safety thanks to flame control with photocell.
Burner Type Burner Capacity Natural Gas Consumption Diesel Consumption Fuel Oil Consumption
  Max. MW Max. kcal/h Max. Nm³/h Max. kg/h Max. kg/h
DIB-600.3 24 20.640.000 2502 2024 2139
 * ØD L H F C K S1 S2 S3 ØM1 ØM2 ØM3 VL DN
DIB 600 EL 3 Ø630 2525 1100 690 1450 950 600 660 708 Ø740 Ø792 Ø860 475  
DIB 600 EL 3 Ø890 2925 1100 690 1000 500 600 660 708 Ø740 Ø792 860 870  
DIB 600 MS 3 Ø630 2525 1100 690 1450 950 600 660 708 Ø740 Ø792 Ø860 475  
DIB 600 MS 3 Ø890 2925 1100 690 1000 500 600 660 708 Ø740 Ø792 860 870  
DIB 600 N 3  Ø698 2525 1100 690 1000 500 600 660 708 Ø740 Ø792 Ø860 475 DN125
DIB 600 N 3  Ø588 2925 1100 690 1000 500 600 660 708 Ø740 Ø792 Ø860 870 DN125
DIB 600 NEL 3  Ø630 2525 1100 690 1450 950 600 660 708 Ø740 Ø792 Ø860 475 DN125
DIB 600 NEL 3  Ø890 2925 1100 690 1000 500 600 660 708 Ø740 Ø792 Ø860 870 DN125
DIB 600 NMS 3  Ø630 2525 1100 690 1450 950 600 660 708 Ø740 Ø792 Ø860 475 DN125
DIB 600 NMS 3  Ø890 2925 1100 690 1000 500 600 660 708 Ø740 Ø792 Ø860 870 DN125

*All dimensions in mm.

SPECIFICATIONS DIB 600 ME DIB 600 EL
Electronic modulating control option
Mechanical modulating control option
Photocell flame control
Internal pilot ignition
ECOSTAR PAL pilot ignition burner
Pilot ignition gas valve
Air pressure switch
Options of operating with Gas / Heavy Oil / Light Oil / Gas-Light Oil / Gas-Heavy Oil
In liquid fuel products, high-pressure mechanic atomization lance or low-pressure air/steam-atomization lance
Ability to operate with hot combustion air*
Different mounting options
Serviceability without dismounting the burner from the boiler / service cover
Different flame tube length
Control via PLC with BMS or software
O2-CO combustion management system connection
Combustion air fan inverter connection
Fuel preparation stations (Gas line/Heavy Oil Station/Light Oil Station)
TSE EN Declaration of Conformity
CE Declaration of Conformity

: Not Included / N/A

: Optional

: Included / Available

ME: Mechanical Modulating

EL: Electronic Modulating