Burner Type | Capacity | Capacity | Natural Gas Consumption | LPG Gas Consumption | Fan Motor Power | Voltage at 50 Hz | ||||
---|---|---|---|---|---|---|---|---|---|---|
Min. kcal/h | Max. kcal/h | Min. kW | Max. kW | Min. Nm³/h | Max. Nm³/h | Min. Nm³/h | Max. Nm³/h | kW | VAC | |
ECO 2.0 G C 1c | 103.200 | 301.000 | 120 | 350 | 12,51 | 36,48 | 4,59 | 13,38 | 0,15 | 1N 240 |
* | L | Gmin | Gmax | H | K | B | C | D | M1 | M2 | N | R | P | Q |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ECO 2.0 G C 1c | 625 | 80 | 250 | 396 | 172 | 455 | 295 | 134 | 195 | 220 | 185 | 230 | 10 | 45 |
*All dimensions in mm.
SPECIFICATIONS | ECO 2.0 G C 1c |
---|---|
Control Type | 1K |
Air flow adjustment | M |
Adjustable flame tube extension | |
Gas Valve | |
Minimum gas pressure switch | |
Maximum gas pressure switch | |
Air pressure switch | |
Flame control | İO |
Ignition | DA |
Sliding boiler connection flange | |
7 pin power supply and first stage socket | |
Complies with TS EN 676 A2 and 2016/426/EC GAR | |
Electrical protection class | IP20 |
: Not Included / N/A
: Optional
: Included / Available
1K: Single Stage
2K: Two Stage
O: Modulating
M: Manuel
SM: Servomotor
İO: Ionization
F: Photocell
DA: Direct Ignition
PA: Pilot Ignition